Contents
Images
Upload your image
DSS Images Other Images
Related articles
A catalog of bright calibrator stars for 200-m baseline near-infrared stellar interferometry We present in this paper a catalog of reference stars suitable forcalibrating infrared interferometric observations. In the K band,visibilities can be calibrated with a precision of 1% on baselines up to200 meters for the whole sky, and up to 300 meters for some part of thesky. This work, extending to longer baselines a previous catalogcompiled by Bordé et al. (2002, A&A, 393, 183), isparticularl y well adapted to hectometric-class interferometers such asthe Very Large Telescope Interferometer (VLTI, Glindemann et al. 2003,Proc. SPIE, 4838, 89) or the CHARA array (ten Brummelaar et al. 2003,Proc. SPIE, 4838, 69) when one is observing well-resolved, high-surfacebrightness objects (K 8). We use the absolute spectro-photometriccalibration method introduced by Cohen et al. (1999, AJ, 117, 1864) toderive the angular diameters of our new set of 948 G8-M0 calibratorstars extracted from the IRAS, 2MASS and MSX catalogs. Angular stellardiameters range from 0.6 mas to 1.8 mas (median is 1.1 mas) with amedian precision of 1.35%. For both the northern and southernhemispheres, the closest calibrator star is always less than 10°away.
| CHARM2: An updated Catalog of High Angular Resolution Measurements We present an update of the Catalog of High Angular ResolutionMeasurements (CHARM, Richichi & Percheron \cite{CHARM}, A&A,386, 492), which includes results available until July 2004. CHARM2 is acompilation of direct measurements by high angular resolution methods,as well as indirect estimates of stellar diameters. Its main goal is toprovide a reference list of sources which can be used for calibrationand verification observations with long-baseline optical and near-IRinterferometers. Single and binary stars are included, as are complexobjects from circumstellar shells to extragalactic sources. The presentupdate provides an increase of almost a factor of two over the previousedition. Additionally, it includes several corrections and improvements,as well as a cross-check with the valuable public release observationsof the ESO Very Large Telescope Interferometer (VLTI). A total of 8231entries for 3238 unique sources are now present in CHARM2. Thisrepresents an increase of a factor of 3.4 and 2.0, respectively, overthe contents of the previous version of CHARM.The catalog is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/431/773
| J - K DENIS photometry of a VLTI-selected sample of bright southern stars We present a photometric survey of bright southern stars carried outusing the DENIS instrument equipped with attenuating filters. Theobservations were carried out not using the survey mode of DENIS, butwith individual target pointings. This project was stimulated by theneed to obtain near-infrared photometry of stars to be used in earlycommissioning observations of the ESO Very Large TelescopeInterferometer, and in particular to establish a network of brightcalibrator sources.We stress that near-infrared photometry is peculiarly lacking for manybright stars. These stars are saturated in 2MASS as well as in regularDENIS observations. The only other observations available for brightinfrared stars are those of the Two Micron Sky Survey dating from overthirty years ago. These were restricted to declinations above≈-30°, and thus cover only about half of the sky accessible fromthe VLTI site.We note that the final 2MASS data release includes photometry of brightstars, obtained by means of point-spread function fitting. However, thismethod only achieves about 30% accuracy, which is not sufficient formost applications.In this work, we present photometry for over 600 stars, each with atleast one and up to eight measurements, in the J and K filters. Typicalaccuracy is at the level of 0\fm05 and 0\fm04 in the J and K_s bands,respectively.Based on observations collected at the European Southern Observatory, LaSilla.Tables 1 and 2 are only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/413/1037
| CHARM: A Catalog of High Angular Resolution Measurements The Catalog of High Angular Resolution Measurements (CHARM) includesmost of the measurements obtained by the techniques of lunaroccultations and long-baseline interferometry at visual and infraredwavelengths, which have appeared in the literature or have otherwisebeen made public until mid-2001. A total of 2432 measurements of 1625sources are included, along with extensive auxiliary information. Inparticular, visual and infrared photometry is included for almost allthe sources. This has been partly extracted from currently availablecatalogs, and partly obtained specifically for CHARM. The main aim is toprovide a compilation of sources which could be used as calibrators orfor science verification purposes by the new generation of largeground-based facilities such as the ESO Very Large Interferometer andthe Keck Interferometer. The Catalog is available in electronic form atthe CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/386/492, and from theauthors on CD-Rom.
| New periodic variables from the Hipparcos epoch photometry Two selection statistics are used to extract new candidate periodicvariables from the epoch photometry of the Hipparcos catalogue. Theprimary selection criterion is a signal-to-noise ratio. The dependenceof this statistic on the number of observations is calibrated usingabout 30000 randomly permuted Hipparcos data sets. A significance levelof 0.1 per cent is used to extract a first batch of candidate variables.The second criterion requires that the optimal frequency be unaffectedif the data are de-trended by low-order polynomials. We find 2675 newcandidate periodic variables, of which the majority (2082) are from theHipparcos`unsolved' variables. Potential problems with theinterpretation of the data (e.g. aliasing) are discussed.
| The Tokyo PMC catalog 90-93: Catalog of positions of 6649 stars observed in 1990 through 1993 with Tokyo photoelectric meridian circle The sixth annual catalog of the Tokyo Photoelectric Meridian Circle(PMC) is presented for 6649 stars which were observed at least two timesin January 1990 through March 1993. The mean positions of the starsobserved are given in the catalog at the corresponding mean epochs ofobservations of individual stars. The coordinates of the catalog arebased on the FK5 system, and referred to the equinox and equator ofJ2000.0. The mean local deviations of the observed positions from theFK5 catalog positions are constructed for the basic FK5 stars to comparewith those of the Tokyo PMC Catalog 89 and preliminary Hipparcos resultsof H30.
| Binary stars unresolved by speckle interferometry. III The KPNO's 4-m telescope was used in 1975-1981 to determine the epochsof 1164 speckle observations for 469 unresolved, known or suspectedbinary stars. The data, presented in tabular form, encompass visualbinaries with eccentric orbits, occultation binaries, astrometricbinaries, Hyades stars of known or suspected duplicity, and many longperiod spectroscopic binaries.
| Photoelectric observations of lunar occultations. XII Occultation observations of 414 events observed between 6 July 1979 and4 September 1980 with the 0.76-m telescope of McDonald Observatory arereported. Timings and data on double stars are given. Angular diameterinformation in six cases is included. The stars concerned with their runnumbers are: SAO 161754 (5270); 94027 (Alpha Tau) (5319, 5381, 5454);159370 (Gamma Lib) (5325, 5571); 162413 (43 Sgr) (5332); 97472 (3 Cnc)(5414); and 93955 (Theta Tau) (5445).
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | Schütze |
Right ascension: | 19h08m44.22s |
Declination: | -18°57'10.0" |
Apparent magnitude: | 6.575 |
Distance: | 296.736 parsecs |
Proper motion RA: | 22 |
Proper motion Dec: | 2.5 |
B-T magnitude: | 8.66 |
V-T magnitude: | 6.748 |
Catalogs and designations:
|